CCL2 Antibody, Clone: [2.2-4H5-01A11], Unconjugated, Mouse, Monoclonal

Artikelnummer: BYT-ORB1272246
Artikelname: CCL2 Antibody, Clone: [2.2-4H5-01A11], Unconjugated, Mouse, Monoclonal
Artikelnummer: BYT-ORB1272246
Hersteller Artikelnummer: orb1272246
Alternativnummer: BYT-ORB1272246-0.5
Hersteller: Biorbyt
Wirt: Mouse
Kategorie: Antikörper
Applikation: ELISA, WB
Spezies Reaktivität: Human
Immunogen: The monoclonal antibody was produced in BALB/c X ICR F1 mice using recombinant hMCP-1/MCAF as the immunizing antigen.
Konjugation: Unconjugated
Alternative Synonym: MCP1, SCYA2, C-C motif chemokine 2, HC11, MCAF, MCP-1, GDCF-2, SMC-CF, HSMCR30
CCL2 Antibody
Klonalität: Monoclonal
Konzentration: batch dependent
Klon-Bezeichnung: [2.2-4H5-01A11]
NCBI: 13500
UniProt: P13500
Formulierung: Lyophilized
Target-Kategorie: CCL2
To a sandwich ELISA (assuming 100ul/well), a concentration of 2.0-4.0 ug/ml of this antibody will detect at least 300 pg/ml of recombinant human MCP-1 when used with antigen affinity purified anti-human MCP-1 (orb1272403) as the detection antibody at a concentration of approximately 0.5-1.0 ug/ml.
To detect hMCP-1 by Western Blot analysis this antibody can be used at a concentration of 0.20-0.40 ug/ml. Used in conjunction with compatible secondary reagents the detection limit for recombinant hMCP-1 is 1.0-2.0 ng/lane, under reducing or non-reducing conditions.
To detect hMCP-1 by Western Blot analysis this antibody can be used at a concentration of 0.20-0.40 ug/ml. Used in conjunction with compatible secondary reagents the detection limit for recombinant hMCP-1 is 1.0-2.0 ng/lane, under reducing or non-reducing conditions.
This antibody stained formalin-fixed, paraffin-embedded sections of human breast invasive ductal carcinoma. The recommended concentration is 10.0 ug/ml with an overnight incubation at 4C. An HRP-labeled polymer detection system was used with a DAB chromogen. Heat induced antigen retrieval with a pH 6.0 sodium citrate buffer is recommended. Optimal concentrations and conditions may vary.
This antibody stained formalin-fixed, paraffin-embedded sections of human breast invasive ductal carcinoma. The recommended concentration is 10.0 ug/ml with an overnight incubation at 4C. An HRP-labeled polymer detection system was used with a DAB chromogen. Heat induced antigen retrieval with a pH 6.0 sodium citrate buffer is recommended. Optimal concentrations and conditions may vary.
This antibody stained formalin-fixed, paraffin-embedded sections of human breast invasive ductal carcinoma. The recommended concentration is 10.0 ug/ml with an overnight incubation at 4C. An HRP-labeled polymer detection system was used with a DAB chromogen. Heat induced antigen retrieval with a pH 6.0 sodium citrate buffer is recommended. Optimal concentrations and conditions may vary.