CCL24 Antibody, Clone: [1.1_6C7-2C5], Unconjugated, Mouse, Monoclonal

Artikelnummer: BYT-ORB1272261
Artikelname: CCL24 Antibody, Clone: [1.1_6C7-2C5], Unconjugated, Mouse, Monoclonal
Artikelnummer: BYT-ORB1272261
Hersteller Artikelnummer: orb1272261
Alternativnummer: BYT-ORB1272261-0.5
Hersteller: Biorbyt
Wirt: Mouse
Kategorie: Antikörper
Applikation: ELISA, WB
Spezies Reaktivität: Human
Immunogen: The monoclonal antibody was produced in BALB/c X ICR F1 mice using recombinant human Eotaxin-2 as the immunizing antigen.
Konjugation: Unconjugated
Alternative Synonym: MPIF2, SCYA24, C-C motif chemokine 24, CK-beta-6, MPIF-2, Ckb-6
CCL24 Antibody
Klonalität: Monoclonal
Konzentration: batch dependent
Klon-Bezeichnung: [1.1_6C7-2C5]
NCBI: 00175
UniProt: O00175
Formulierung: Lyophilized
Target-Kategorie: CCL24
To a sandwich ELISA (assuming 100ul/well), a concentration of 2.0-4.0 ug/ml of this antibody will detect at least 80.0 pg/well of recombinant human Eotaxin-2 when used with antigen affinity purified anti-human Eotaxin-2 (orb1272559) as the detection antibody at a concentration of approximately 1.0-2.0 ug/ml.
To detect hEotaxin-2 by Western Blot analysis this antibody can be used at a concentration of 0.25-0.50 ug/ml. Used in conjunction with compatible secondary reagents the detection limit for recombinant hEotaxin-2 is 0.5-1.0 ng/lane, under non-reducing conditions.
To detect hEotaxin-2 by Western Blot analysis this antibody can be used at a concentration of 0.25-0.50 ug/ml. Used in conjunction with compatible secondary reagents the detection limit for recombinant hEotaxin-2 is 0.5-1.0 ng/lane, under non-reducing conditions.
This antibody stained formalin-fixed, paraffin-embedded sections of human tonsil. The recommended concentration is 10.0 ug/ml with an overnight incubation at 4C. An HRP-labeled polymer detection system was used with a DAB chromogen. Heat induced antigen retrieval with a pH 8.0 EDTA buffer is recommended. Optimal concentrations and conditions may vary.
This antibody stained formalin-fixed, paraffin-embedded sections of human tonsil. The recommended concentration is 10.0 ug/ml with an overnight incubation at 4C. An HRP-labeled polymer detection system was used with a DAB chromogen. Heat induced antigen retrieval with a pH 8.0 EDTA buffer is recommended. Optimal concentrations and conditions may vary.
This antibody stained formalin-fixed, paraffin-embedded sections of human tonsil. The recommended concentration is 10.0 ug/ml with an overnight incubation at 4C. An HRP-labeled polymer detection system was used with a DAB chromogen. Heat induced antigen retrieval with a pH 8.0 EDTA buffer is recommended. Optimal concentrations and conditions may vary.